| 例文 |
Accessory componentの部分一致の例文一覧と使い方
該当件数 : 104件
The multilayer ceramic capacitor includes a plurality of dielectric ceramic layers and a plurality of internal electrodes formed along a particular interface between the dielectric ceramic layers, and each dielectric ceramic layer includes a dielectric ceramic containing a perovskite compound represented by ABO_3 as a principal component and R (R is La and the like), M (M is Mn and the like) and Si as accessory components.例文帳に追加
複数の誘電体セラミック層および誘電体セラミック層間の特定の界面に沿って形成された複数の内部電極を備え、誘電体セラミック層が、ABO_3で表わされるペロブスカイト型化合物を主成分とし、副成分として、R(Rは、La等)、M(Mは、Mn等)およびSiを含む、誘電体セラミックからなる。 - 特許庁
(j) reproduce or imitate the officially recognized name, armorial bearings, flags and other emblems, abbreviations or names or abbreviated names of any State or international organization without the permission of the competent authority of the State or international organization concerned; such signs may in any case only be registered where they constitute an accessory feature in relation to the main distinguishing component;例文帳に追加
(j) 公式に認められている国又は国際機関の名称,紋章,旗章その他の記章,略語,名称若しくは略称を当該の国若しくは国際機関の権限ある官庁の許可なく複製又は模倣した標識。このような標識は,如何なる場合にも,識別性ある主要な標識の副次的な要素である場合にのみ登録が可能である。 - 特許庁
On the basis of the output value, the accessory circuit 136 performs any one of mute processing for cutting off output of a reception station signal from a detection circuit 124; high-cut processing for cutting off output of a high frequency band component in the reception station signal, and processing for mixing right and left components of the reception station signal and switching stereo playback based on the relevant reception station signal to monaural playback.例文帳に追加
アクセサリ回路136は、この出力値に基づいて、検波回路124からの受信局信号の出力を遮断するミュート処理、受信局信号の高周波帯域成分の出力を遮断するハイカット処理、受信局信号の左右成分を混合して当該受信局信号に基づくステレオ再生をモノラル再生へ切り替える処理のいずれかを行う。 - 特許庁
The pressure monitoring system starts the measurement of blood pressures in a cuff type sphygmomanometer based on an excess of over a preset criterion range by changes in the frequency component analysis values determined by analyzing into frequency components the heartbeat cycle given as the cycle of continuous beating of a heart with a photoelectric pulse wave sensor or a cardiographic electrode handily applicable on a skin of the living body or without an accessory sensor.例文帳に追加
生体の表皮上に簡易に装着することができる光電脈波センサ、または心電電極、もしくは付属センサ無しに、連続的な心臓拍動周期による心拍周期を周波数成分に分解することにより周波数成分分析値の変動が予め設定された判断基準範囲を越えたことに基づいてカフ式血圧計の血圧測定を起動させる血圧監視装置。 - 特許庁
| 例文 |
|
ログイン |
Weblio会員(無料)になると
|
|
ログイン |
Weblio会員(無料)になると
|