INCIDENT-LIGHT FLUORESCENCE STEREOSCOPIC MICROSCOPE例文帳に追加
落射型蛍光立体顕微鏡 - 特許庁
FLUORESCENCE CUBE, AND INCIDENT-LIGHT FLOODLIGHTING PIPE OR OPTICAL MICROSCOPE PROVIDED WITH THE SAME例文帳に追加
蛍光キューブ及びそれを備えた落射投光管又は光学顕微鏡 - 特許庁
To provide a fluorescence microscope equipped with a light shielding member covering the whole or a part of the fluorescence microscope so that external light can not be made incident on a sample, and improved to save time and labor in operation required when the microscope is switched from bright field observation by a light source for bright field transmissive illumination to fluorescence observation by a light source for fluorescence vertical illumination.例文帳に追加
試料に外光が入射しないように蛍光顕微鏡の全体又は一部を覆う遮光部材を備えた蛍光顕微鏡において、明視野透過照明用光源による明視野観察から蛍光落射用光源による蛍光観察に切り替える際に必要な操作の手間を省く。 - 特許庁
The confocal scanning microscope 1 makes the fluorescence generated from the sample 12 incident on the light separation means 3 via the objective optical system 6, to separate the fluorescence from the exciting light and detects the fluorescence by an imaging element 19 via an imaging optical system 13.例文帳に追加
共焦点走査型顕微鏡1は、試料12から生じた蛍光を、対物光学系6を介して光分離手段3へ入射させ励起光から分離し、撮像光学系13を介して撮像素子19で検出する。 - 特許庁
Fluorescence from a sample 26 placed in a confocal inverted optical microscope 19 and excitation laser light are allowed to be simultaneously incident on a nonlinear optical element 32 to generate sum frequency light 34.例文帳に追加
共焦点倒立光学顕微鏡19に設置された試料26からの蛍光と、励起レーザ光を非線形光学素子32に同時に入射させ、和周波光34を発生させる。 - 特許庁
To make a laser beam incident on a microscope main body as parallel light of a uniform beam diameter without reducing joint efficiency relative to an optical fiber even in the case where a wavelength changes when fluorescence observation is carried out such that a laser beam emitted from the laser light source is guided to a microscope main body by the use of the optical fiber.例文帳に追加
レーザ光源から出射されたレーザ光を光ファイバを用いて顕微鏡本体に導入して蛍光観察を行う際に、波長が変化しても光ファイバへの結合効率を低下させることなく、かつ、均一なビーム径の平行光として顕微鏡本体に入射させる。 - 特許庁
The total reflection fluorescence microscope makes the change over of vertical illumination and total reflection illumination possible by changing the incident angle of the illumination light to be radiated to a sample through an objective lens 7 from a laser beam source, in which the incident angle of the illumination light from the objective lens 7 on the sample is regulated to a range making the total reflection illumination obtainable.例文帳に追加
レーザ光源から対物レンズ7を介して試料に照射される照明光の入射角を変化させ落射照明と全反射照明の切換えを可能にした全反射蛍光顕微鏡であって、照明光の対物レンズ7から試料への入射角を全反射照明が得られる範囲に規制する。 - 特許庁
-
履歴機能過去に調べた
単語を確認! -
語彙力診断診断回数が
増える! -
マイ単語帳便利な
学習機能付き! -
マイ例文帳文章で
単語を理解!
|
意味 | 例文 (7件) |
|
ピン留めアイコンをクリックすると単語とその意味を画面の右側に残しておくことができます。 |
ログイン |
Weblio会員(無料)になると 検索履歴を保存できる! 語彙力診断の実施回数増加! |
「incident-light fluorescence microscope」のお隣キーワード |
weblioのその他のサービス
ログイン |
Weblio会員(無料)になると 検索履歴を保存できる! 語彙力診断の実施回数増加! |