意味 | 例文 (28件) |
低周波電力計の英語
追加できません
(登録数上限)
「低周波電力計」の部分一致の例文検索結果
該当件数 : 28件
低消費電力で低コストな水晶発振器を用いて、周波数安定度の高い高精度な周波数出力が得られ、発振周波数を校正する作業の必要がない小型でかつ低消費電力で低コストな水晶発振回路および時計装置および計測装置を提供する。例文帳に追加
To provide a crystal oscillation circuit, a clock device and a measuring instrument, with which the highly accurate frequency output with high frequency stability can be obtained while using the crystal oscillator of low power consumption and low cost, power consumption is reduced and costs are reduced while being miniaturized without requiring work for calibrating an oscillation frequency. - 特許庁
柔軟なネットワーク設計を妨げることなく、波長分散や、周波数依存の回路特性により生じる干渉電力を低減させる。例文帳に追加
To reduce interference power generated by wavelength dispersion and circuit characteristics of frequency dependency without preventing flexible network design. - 特許庁
電力消費を低減するように、無線周波数(RF)における増幅ステージの設計及び制御を改善した送信器を提供する。例文帳に追加
To provide a transmitter with improved design and control of amplification stages in a radio frequency (RF), so as to reduce its power consumption. - 特許庁
電力会社のブレーカ及び需要家の電力量計による高周波信号の信号損失を低減し、且つ設置工事の安全性の確保及び作業効率の向上を実現した電力線通信システムを提供する。例文帳に追加
To provide a power line communication system capable of reducing the signal loss of high frequency signals in the breakers of a power company and power consumer's watthour meters, securing the safety of installation work and improving the working efficiency. - 特許庁
計測に用いるクロックの周波数を適切に制御することにより、計測精度を維持しながら体温計測時以外の消費電力を低減する電子体温計を提供する。例文帳に追加
To provide an electronic medical thermometer that reduces power consumption when not in use for measuring body temperature while maintaining measuring accuracy by appropriately controlling the frequency of clocks used for measurement. - 特許庁
計測に用いるクロックの周波数を適切に制御することにより、計測精度を維持しながら体温計測時以外の消費電力を低減する電子体温計を提供する。例文帳に追加
To provide an electronic body thermometer for reducing a power consumption in a period other than a body temperature measuring time, while keeping measurement accuracy, by controlling properly a frequency of a clock used for measurement. - 特許庁
位相ロックループ周波数シンセサイザ設計における、大きな電圧制御発振器範囲(例えば、487MHz)、(例えば)1.2V電力供給電圧、および低い電力消費の要求を達成する。例文帳に追加
To comply with demands for a large voltage-controlled oscillation range (for example, 487 MHz), a desired supply voltage (for example, 1.2V), and low power consumption in designing a phase-locked loop frequency synthesizer. - 特許庁
-
履歴機能過去に調べた
単語を確認! -
語彙力診断診断回数が
増える! -
マイ単語帳便利な
学習機能付き! -
マイ例文帳文章で
単語を理解!
「低周波電力計」の部分一致の例文検索結果
該当件数 : 28件
MR素子を利用した電子式流量計において、電池駆動の低周波クロックCPUでの流量積算処理を流量信号の周波数が高くなってもミスカウントをおこなうことなく、低消費電力で高精度な流量積算処理が行えるようにする。例文帳に追加
To attain flow rate integration processing in a low frequency clock CPU driven by a battery with low power consumption and high precision without operating any miss count even when the frequencies of a flow rate signal are made high. - 特許庁
そして、CPUレジスタ1aで管理されるクロック周波数の書換えを行なう前に、予めユーザが指定した省電力レベルに応じて計算されたクロック周波数の上限値のデータをBIOS−ROM6から読み出して、この値と、OSの処理の種別に応じて計算されたクロック周波数の値を比較して低い方の値を判別する。例文帳に追加
Then, prior to rewriting of the clock frequency managed at a CPU register 1a, data on the upper limit value of the clock frequency calculated in accordance with the level of power savings specified by a user in advance is read from a BIOS-ROM 6, and this value is compared with the value of the clock frequency calculated in accordance with the type of processing of the OS to determine which is lower. - 特許庁
間欠受信が続く期間中でも、低速クロックの周波数偏差の計算の頻度を減らし、補正値計算に費やされる消費電力の削減を行うこと。例文帳に追加
To provide a timing controller that reduces a frequency of calculation of a frequency deviation for a low speed clock even for a period when intermittent reception is consecutive so as to reduce the power consumption used for calculating a correction value. - 特許庁
OS20は、CPU30が複数の対応プロセスを処理するときの処理時間に基づいて、CPU30の消費電力を低減するための算出設定動作周波数を計算し、設定動作周波数として対応イベント識別子に対応付けてテーブル25に格納する。例文帳に追加
The OS 20 computes computed set operation frequency for reducing the power consumption of the CPU 30 based on a processing time when the CPU 30 processes a plurality of corresponding processes, and stores in the table 25 the computed set operation frequency as set operation frequency in association with the corresponding event identifier. - 特許庁
高速再生時の発振最高周波数を抑え、消費電力の低減、アナログ部品やデジタル同期回路の設計負担、開発コストの低減を図るデータ再生装置を得る。例文帳に追加
To obtain a data reproducing device for reducing power consumption, and also reducing design burden of analog components and a digital synchronous circuit, and development cost by suppressing the oscillation highest frequency during high-speed reproduction. - 特許庁
バッテリーの充放電電流の積算値を監視、計測するために、低周波のA/D変換用クロックを使用しながら低消費電力化を図り且つダイナミックレンジを拡大すること。例文帳に追加
To provide an integral type analog/digital converter that uses a low frequency analog/digital conversion clock in order to monitor and measure an integral value of battery charging/discharging currents with low power consumption and extended dynamic range. - 特許庁
直流オフセットの低減対策を施した受信器、および周波数変換に必要な周辺機器の設計が容易であり、かつ低省電力化を実現できる受信装置および送信装置を提供する。例文帳に追加
To provide a receiver which has reduced DC offset and to provide a receiver and a transmitter wherein the design of peripheral devices required for frequency conversion is easy and low power consumption can be realized. - 特許庁
構造の単純化、高性能化、小型集積化、設計の容易化、低消費電力化、低コスト化を実現可能なマイクロ波・ミリ波帯の高周波パルス信号発生装置を提供する。例文帳に追加
To provide a high frequency pulse signal generation device of a microwave/millimeter wave band which can achieve a simple structure, high performance, compact integration, ease of design, low power consumption and a reduced cost. - 特許庁
|
意味 | 例文 (28件) |
|
低周波電力計のページの著作権
英和・和英辞典
情報提供元は
参加元一覧
にて確認できます。
Copyright(c)2024 総務省 統計局 All rights reserved 政府統計の総合窓口(e-Stat) |
ピン留めアイコンをクリックすると単語とその意味を画面の右側に残しておくことができます。 |
ログイン |
Weblio会員(無料)になると 検索履歴を保存できる! 語彙力診断の実施回数増加! |
-
1unmet
-
2硬貨
-
3destiny
-
4while
-
5leave
-
6consider
-
7present
-
8appreciate
-
9address
-
10experience
「低周波電力計」のお隣キーワード |
weblioのその他のサービス
ログイン |
Weblio会員(無料)になると 検索履歴を保存できる! 語彙力診断の実施回数増加! |