difference thresholdの部分一致の例文一覧と使い方
該当件数 : 1424件
Then, when the detected shape is within the predetermined pedestrian's shape range set by assuming the detected shape is a shape of the pedestrian, and the width varies equally to or more than a predetermined difference within the pedestrian's shape range, the predetermined pedestrian load range as a threshold for determining the pedestrian collision is expanded more than a case when the width does not vary more than the predetermined difference.例文帳に追加
そして、その検出形状が歩行者のものであるとして設定した所定の歩行者形状範囲内にありかつその横幅がその歩行者形状範囲内において所定差以上に変化する場合には、その所定差以上の変化が生じない場合に比して、上記した歩行者衝突判定のための閾値としての所定の歩行者荷重範囲を拡大する。 - 特許庁
A voice/nonvoice discriminating section 106 judges that a section of the voice spectrum is a voice section containing a voice component if the difference between the voice spectrum signal and the value of a noise base is a prescribed threshold or more and otherwise judges that the section is a nonvoice section containing no voice components and containing only noise.例文帳に追加
音声非音声識別部106は、音声スペクトル信号とノイズベースの値の差が所定の閾値以上である場合、音声成分を含む有音部分と判定し、それ以外の場合、音声成分を含まない雑音のみの無音部分であると判定する。 - 特許庁
A value of a difference corresponding to a maximal value among count values exceeding a threshold or count values of differences obtained for all points on the minimum cost path is obtained as head position information L indicating a position in the speech signal S1, of a head sample of the reference signal.例文帳に追加
そして、閾値を超えたカウント値、または最小コストパス上の全ての点について求めた差分のカウント値のうちの最大値に対応する差分の値を、参照信号の先頭サンプルが音声信号S1における位置を示す先頭位置情報Lとして求める。 - 特許庁
A term when the switch SW1 is turned on and the switch SW2 is turned off is controlled so as to be longer than a time when voltage of both ends of the capacitor C1 is charged to voltage obtained by subtracting threshold voltage of the transistor M1 from a potential difference between VDD and GND.例文帳に追加
スイッチSW1がONしスイッチSW2がOFFしている期間が、キャパシタC1の両端の電圧がVDDとGND間の電位差からトランジスタM1の閾値電圧を差し引いた電圧に充電されるまでの時間よりも長くなるよう制御する。 - 特許庁
When it is determined by the comparison means that each flow rate value has the difference over the prescribed threshold, a flow rate operation means determines the final flow rate by removing a low-level flow rate value and by using only a high-level flow rate value.例文帳に追加
そして流量演算手段においては、上記比較手段により各流量値に所定の閾値以上の差があると判定されたときには、レベルの低い流量値を排除し、レベルの高い流量値だけを用いて最終的な流量を求める。 - 特許庁
When a mountain is crossed or when a down slope section capable of recovering big regeneration energy (difference in elevation is not smaller than a threshold value) is present on the passage, SOC management width is enlarged temporarily and regeneration energy is recovered within the enlarged management width.例文帳に追加
本実施の形態では、山越えを行うときなど、経路上に大きな回生エネルギーを回収できる下り区間(標高差が閾値以上の下り区間)がある場合、一時的にSOC管理幅を拡大し、この拡大した管理幅内で回生エネルギーを回収する。 - 特許庁
An interference detection part 80 calculates an average value of received power from a reception signal corresponding to waves received by reception antennas 31 and 32 and determines that the interference occurs when a difference from a previously calculated average value of the received power is a threshold value or larger.例文帳に追加
干渉検出部80は、受信アンテナ31、32で受信した受信波に対応する受信信号から受信電力の平均値を演算し、前回演算した受信電力の平均値との差が閾値以上のときに干渉が発生したと判断する。 - 特許庁
A pulse light acquiring part 17 finds a level of a reflected infrared pulse from a difference between the differential and integral value and the combined differential and integral value, and a detection determination means 19 compares the level of the reflected infrared pulse with a threshold to detect the presence of the object.例文帳に追加
パルス光取得手部17が微分値積分量と組合せ微分値積分量との差分から反射赤外線パルスの大きさを求め、検知判定手段19は反射赤外線パルスの大きさと閾値とを比較して物体の有無を検知する。 - 特許庁
The difference in the oil pressure (differential pressure) existing between a pair of oil pressure chambers constituting an actuator for changing the gear ratio of a toroidal type continuously variable transmission is correlated with the road surface situation previously (the threshold for the differential pressure complying with the road surface situation is set previously).例文帳に追加
トロイダル型無段変速機の変速比を変化させる為のアクチュエータを構成する1対の油圧室同士の間に存在する油圧の差(差圧)と、上記路面状況とを予め対応させておく(路面状況に応じた差圧の閾値を予め設定しておく)。 - 特許庁
When the density of the noticed pixel has a density difference of a threshold or more for the density of a pixel on a prescribed pixel position in either of the first dust detection circuit 82 and the second dust detection circuit 83, the noticed pixel is detected as a noise pixel.例文帳に追加
そして、第1ゴミ検出回路82および第2ゴミ検出回路83は注目画素の濃度が所定の画素位置における画素の濃度に対して、いずれか一方が閾値以上の濃度差を有していれば、当該注目画素をノイズ画素として検出する。 - 特許庁
When a collision prediction level α exceeds a threshold α2 (S116), the pressurizing amount reference value Ps stored at the time is set as a reference value and brake assist force according increase difference of master pressure P from the pressurizing amount reference value Ps is generated (S118, S120).例文帳に追加
衝突予知レベルαがしきい値α2を越えると(S116)、この時点で記憶されている加圧量基準値Psと基準として、この加圧量基準値Psからのマスタ圧Pの増加偏差に応じたブレーキアシスト力を発生させる(S118,S120)。 - 特許庁
In case that such a fault that the input voltage of the control terminal f of SW-RG goes high abnormally occurs and that the SW-RG controls the output voltage to be lower, a detection control circuit 7 detects the voltage difference being under a first threshold, and grounds the control terminal f.例文帳に追加
SW−RGの制御端子fの入力電圧が異常に高くなる故障が生じて、SW−RGが出力電圧を降下制御した場合、検出制御回路7が電圧差の第1の閾値未満を検出し、制御端子fを接地する。 - 特許庁
In a 1st composition, if the difference between the voltage across the capacitor 20 and the voltage across the fuel cell 50 at the time of an open circuit is a predetermined threshold value or more, in the case a fuel cell 50 is to be connected to power supply wiring, the chopping control is carried out to a switch 32.例文帳に追加
第1の構成では、燃料電池50を電源配線に接続しようとする際に、キャパシタ20の両端電圧と燃料電池50の開放時の両端電圧との差異が所定の閾値以上である場合に、スイッチ32をチョッピング制御する。 - 特許庁
When the absolute value |x| of the difference between object data to be decided (large black triangle) and data (larger white triangle) written last to a recording memory 8 is larger than a threshold, it is considered that the degree of variation of the object data to be decided is large and the data are written to the recording memory 8.例文帳に追加
判定対象のデータ(大きな黒三角形)と前回記録メモリ8に書き込んだデータ(大きな白三角形)との差の絶対値|x|がしきい値よりも大きいときには、判定対象のデータの変化の度合いが大きいとして、記録メモリ8に書き込む。 - 特許庁
The traveling control part 10 estimates the self-position by using the angular speed ωg when a difference between the angular speed ωm calculated by the angular speed calculation part 5 and the angular speed ωg from the gyro 6 is larger than a threshold ωth, and using the angular speed ωm in the other case.例文帳に追加
走行制御部10は、角速度算出部5により算出された角速度ωmとジャイロ6からの角速度ωgとの差が閾値ωthよりも大きいとき角速度ωgを用い、そうでないとき、角速度ωmを用いて自己位置を推定する。 - 特許庁
Even when a yaw rate difference Δγ exceeds an under steer determination threshold γth and the determination of the step S2 becomes Yes in the under steer suppressing control, a wheel 3 on the turning inside is not braked since the determination of the step S3 becomes No.例文帳に追加
これにより、アンダステア抑制制御においては、ヨーレイト差Δγがアンダステア判定閾値γthを超えてステップS2の判定がYesとなった場合にも、ステップS3の判定がNoとなるため、旋回内側のホイール3が制動されることがなくなる。 - 特許庁
A threshold voltage offset of a transistor provided in the sense amplifier circuit can be then removed by the sense amplifier circuit under control of an offset control circuit and in such a case, the auxiliary circuit is utilized to stabilize the voltage difference after sharing the charge on the bit line.例文帳に追加
そして、オフセット制御回路の制御を受ける感知増幅回路により、感知増幅回路に備えられるトランジスタのしきい電圧オフセットを除去でき、この際、ビットラインでの電荷共有後の電圧差を安定化させるために補助回路が利用される。 - 特許庁
When the difference between a maximum value and a minimum value of voltages of cells C1 to C8 is larger than a predetermined threshold value, the voltages of the cells C1 to C8 are judged to have the variation, and the variation in the voltages of the cells C1 to C8 is adjusted so as to be reduced by performing charging and discharging.例文帳に追加
セルC1〜C8の電圧の最大値と最小値の差が所定の閾値よりも大きいとき、セルC1〜C8の電圧にばらつきがあると判定し、充放電を行うことによりセルC1〜C8の電圧のばらつきを小さくするように調整する。 - 特許庁
When the last value exists, the device discriminates that the sampling signal reaches reset noise by this time setting value if a difference of the last value and current value is equal or more than the threshold value, and establishes the phase of the sampling signal to a position in which the AFE 133 samples a hold unit of the CCD output.例文帳に追加
前回値がある場合は、今回値との差分がしきい値以上であれば今回の設定値にてリセットノイズにサンプリング信号が達したと判定し、サンプリング信号の位相をAFE133でCCD出力のホールド部をサンプルできる位置に設定する。 - 特許庁
The device performs the spotlight discrimination of a photographed image according to whether luminance distribution on a screen smoothly changes in a mountain shape (S202), a difference of the luminance values in a center part and a peripheral part (S204), and a ratio of pixels with luminance values more than a threshold value in the center part (S206).例文帳に追加
画面上の輝度分布が山状になだらかに変化しているか(S202)、中央部と周辺部の輝度値の差分(S204)、中央部において閾値以上の輝度値を有する画素の割合(S206)、に応じて、撮影画像のスポットライト判定を行う。 - 特許庁
To provide an electric tool which eliminates the deviation between a threshold and the lower limit in the usable range of the battery voltage, the deviation caused by the difference of the voltage ranges of each battery pack, and which performs good overdischarge prevention control even when battery packs in different voltage ranges are selected to be mounted.例文帳に追加
電池パック毎の電圧帯に違いによる電池電圧の利用可能な範囲の下限と閾値のずれを解消し、電圧帯の異なる電池パックを選択的に装着しても過放電防止制御を良好に行える電動工具を提供する。 - 特許庁
Subsequently the shape data creation system 1 provides the target portion dot sequence data with modification for changing a shape corresponding to the target portion dot sequence data so that a difference between the converted target portion waveform data and the new waveform data becomes equal to or less than a predetermined threshold.例文帳に追加
続いて、形状データ作成システム1は、変換された対象部位波形データと、新規波形データとの差異が所定の閾値以下となるように、対象部位点列データに対応する形状を変形させる修正を当該対象部位点列データに行う。 - 特許庁
When the difference is larger than a set threshold value, it is determined that slip occurs in a driving wheel to loosen control of clutch stroke or convert in the opposite direction.例文帳に追加
車両の駆動輪回転速度(ωd)と従動輪回転速度(ωf)との差分を繰り返し演算し、その差分が設定された閾値より大きいときには、駆動輪にスリップが発生しているものとして、クラッチ・ストロークの制御を緩やかにする、もしくは反対方向に転換する。 - 特許庁
Then, the sum of the absolute values of the threshold voltage of the first semiconductor switching element 42 constituting the amplifier 30 and the second semiconductor switching element 52 is set to be a value equal to or larger than the absolute value of a potential difference between the first potential and the second potential.例文帳に追加
そして、信号反転増幅器30を構成する第1の半導体スイッチング素子42と、第2の半導体スイッチング素子52のスレッシュホールド電圧の絶対値の和が、前記第1の電位および第2の電位の電位差の絶対値以上の値に設定されている。 - 特許庁
Then, when the difference DLTPI between the average vale PIAVE of the indicated average effective pressure of cylinders other than the specific one and the indicated average effective pressure PIR of the specific cylinder exceeds the threshold DLTPILMT, it is judged that the specific cylinder exceeds the stability limit.例文帳に追加
そして、前記特定気筒以外の気筒の図示平均有効圧の平均値PIAVEと、前記特定気筒の図示平均有効圧PIRとの差DLTPIが、閾値DLTPILMTを超えると、前記特定気筒が安定度限界を超えたと判断する。 - 特許庁
An RS flip-flop is set when an input data exceeds a threshold value, the maximum value data of a positive peak P2 in the input data is detected/held, and the RS flip-flop is reset thereafter when a difference between the maximum value data and the input data exceeds a set value (time t4).例文帳に追加
入力データが閾値を越えるとRSフリップフロップはセットされ、入力データの正ピークP2の最大値データを検出・保持した後、その最大値データと入力データとの差分が設定値を越えたならば(時刻t4)RSフリップフロップはリセットされる。 - 特許庁
The flatness monitoring section is placed in a proximity region in the peripheral region, the proximity region being close to the pixel region in such a manner that a level difference between a part of the surface of the insulating film overlapping the plurality of the pixels and another part of the surface overlapping the flatness monitoring section does not exceed a prescribed threshold.例文帳に追加
平坦度モニタ部は、周辺領域のうち複数の画素部に重なる表面の一部分と平坦度モニタ部に重なる表面の他の部分との段差が所定閾値を超えないまでに画素領域に接近する、接近領域に配置されている。 - 特許庁
A dot clock correction circuit 52 obtains a difference between a logical pulse number of a dot clock obtained from the encoder pulse and the pulse number of an actual dot clock and compares it with a prescribed threshold value and changes the frequency division ratio of the dot clock generation circuit 51 in accordance with the result in the comparison.例文帳に追加
ドットクロック補正回路52は、エンコーダパルスから求められたドットクロックの理論上のパルス数と実際のドットクロックのパルス数との差を求めて所定のしきい値と比較し、比較結果に応じてドットクロック発生回路51の分周比を変更する。 - 特許庁
The primary determining part comparatively calculates the concentration of a pixel to be noted at a center shown in figure 5 (b) with the concentration of the peripheral pixels by using an edge detection window shown in (a) so as to compare the concentration difference with an edge threshold, and determines the edge part/non-edge part of the pixel to be noted.例文帳に追加
一次判定部は、図5(a)に示すエッジ検出ウィンドウを用い、(b)に示すように中央の注目画素の濃度と周囲の画素の濃度とを比較演算してその濃度差をエッジ閾値と比較し、注目画素のエッジ部/非エッジ部を判定する。 - 特許庁
Based on detection results by a first detection means and a second detection means, it is determined whether a difference between a game ball discharged to a game area 27 and a game ball that has passed through collection parts has reached a threshold for determination in failure, and control in failure is executed.例文帳に追加
第1検出手段と第2検出手段との検出結果にもとづいて、遊技領域27に発射した遊技玉と回収部を通過した遊技玉との差分が異常時判定用の閾値に達したか否かを判定し、異常時制御を実行する。 - 特許庁
The detection value of a second angular velocity sensor after offset correction is corrected based on the reference value, and when a difference value between the corrected value and the detection value of the first angular velocity sensor after offset correction exceeds a given determination threshold, it is determined that either one is faulty.例文帳に追加
そして、基準値に基づいてオフセット補正後の第2角速度の検出値を補正するとともに、該補正値とオフセット補正後の第1角速度センサの検出値との差分値が所定の判定閾値を超えるとき、いずれか一方が故障であると判定する。 - 特許庁
When the difference between the achieved size of the subject and the reference size of the subject exceeds a predetermined threshold value and the position of the zoom lens reaches a wide-angle end or a telephoto end, the imaging device updates the reference size on the basis of the achieved size of the subject.例文帳に追加
そして、撮像装置が、取得された被写体のサイズと被写体の基準サイズとの差が所定の閾値を超えており、かつ、ズームレンズの位置が広角端又は望遠端に達している場合に、上記取得された被写体のサイズで基準サイズを更新する。 - 特許庁
Prior to the filtering processing, among the pixel values used for the filtering processing, pixel values such that absolute values of difference between the relevant pixel value and the pixel to be corrected are larger than a specified threshold are replaced with the pixel value of the pixel to be corrected.例文帳に追加
フィルタリング処理に先立って、フィルタリング処理に用いる画素値のうち、当該画素値と補正対象画素の画素値との差の絶対値が所定のしきい値以上である画素値については、その画素値を前記補正対象画素の画素値で置き換えておく。 - 特許庁
Program ending time with respect to an input image signal is obtained from EPG data separated by a decoder 12 and a threshold for detecting the telop is variably controlled by a telop information detection part 5 based on difference between the program ending time and the current time.例文帳に追加
デコーダ12により分離されたEPGデータから、入力画像信号に係る番組終了時刻を求め、該番組終了時刻と現在時刻との差に基づき、テロップ情報検出部5においてテロップを検出するための閾値を可変制御する。 - 特許庁
When the rotational speed difference reaches the threshold or exceeds it, and simultaneously when the wheel acceleration for the front wheel is negative and the wheel acceleration for the rear wheel is positive, a vehicle driving device is operated by an actuator device 105.例文帳に追加
回転速度差がそのしきい値に到達したときまたはそれを超えたとき、同時に前車輪に対する車輪加速度が負でありかつ後車輪に対する車輪加速度が正であるときにアクチュエータ装置105により車両駆動装置が操作される。 - 特許庁
When pressure differential in front and behind a throttle valve is large, a pressure ratio RP between manifold pressure Pm and atmospheric pressure Pa is calculated, and when pressure difference in front and behind the throttle valve is small, the manifold pressure Pm is fixed to a differential pressure threshold value and the pressure ratio RP is calculated.例文帳に追加
スロットルバルブ前後の圧力差が大きいときには、マニホルド圧Pmと大気圧Paとの圧力比RPを算出し、一方、スロットルバルブ前後の圧力差が小さいときには、マニホルド圧Pmを差圧限界値に固定して圧力比RPを算出する。 - 特許庁
A requirement deciding part 50 compares the battery temperature Tb1 of the power accumulating part and a predetermined temperature management value Tb1^*; and when there is a difference between both the temperature and the value which exceeds a prescribed threshold, the requirement determining part creates temperature rise demand or a cooling demand.例文帳に追加
要求判断部50は、蓄電部の電池温度Tb1と、予め定められる温度管理値Tb1^*とを比較し、両者の間に所定のしきい値温度以上の偏差が生じていれば、昇温要求または冷却要求を生成する。 - 特許庁
By this resistance control, the PMOS transistor 15m makes output from the memory cell array 16m as voltage and can input it to a sense amplifier circuit 18 so that degradation of threshold voltage difference of the memory cell of the memory cell array 16m due to repetition of rewriting operation is corrected.例文帳に追加
この抵抗制御により、PMOSトランジスタ15mは、書き換え動作の繰り返しによるメモリセルアレイ16mのメモリセルの閾値電圧差の低下を補正するように、メモリセルアレイ16mからの出力を電圧にして、センスアンプ回路18に入力できる。 - 特許庁
A feature amount generation processing section compares a pixel difference value of two pixels in a local area specifying the position of the detected feature point as a reference with a threshold and generates binary information showing the comparison result as one component of feature amount corresponding to the feature point.例文帳に追加
特徴量生成処理部は、検出した特徴点の位置を基準とした局所領域内における二画素の画素差分値を閾値と比較して、比較結果を示す二値化情報を特徴点に対応する特徴量の一成分として生成する。 - 特許庁
The crew detection ECU 3 has an adjustment value ΔW_0 that is a difference to a design value W_0 in the vacant seat 0 point load value, and the adjustment value ΔW_0 is used as an adjustment value for design values W_th1, W_th2 of the crew discrimination threshold.例文帳に追加
乗員検知ECU3は、空席0点荷重値の設計値W_0に対する差分である調整値ΔW_0を持ち、調整値ΔW_0は、乗員判別しきい値の設計値W_th1、W_th2に対する調整値として使用されていることを特徴とする。 - 特許庁
In a manufacturing process of a welded wide flange shape to form the wide flange shape by welding/joining a web material to an upper/ lower pair of flange materials, a flange 31 outer face, where a temperature difference of upper/lower exceeds a threshold value after welding, is cooled unsymmetrically in upper/lower (QT≠QB and/or PT≠PB).例文帳に追加
上下1対のフランジ材にウエブ材を溶接結合してH形鋼を形成する溶接H形鋼の製造過程で、溶接後の上下の温度差が閾値を超えたフランジ31外面を上下非対称(Q_T ≠Q_B および/またはP_T ≠P_B )に冷却する。 - 特許庁
When an average pitch difference DN(i) between the singing voice pitch vn0(k) and a pitch of a specific musical sound k is equal to or higher than a threshold Th (S180:YES), a correction amount GS(i+1) for a unit section (i+1) is derived (S190).例文帳に追加
その歌声音高vn0(k)を、特定楽音kの音高との間の音高差である平均音高差分DN(i)が閾値Th以上であれば(S180:YES)、単位区間(i+1)に対する修正量GS(i+1)を導出する(S190)。 - 特許庁
A voice/non-voice identifying part 106 judges a part to be a sound part comprising a voice component when a difference between a voice spectrum signal and a noise base value is equal to or more than a prescribed threshold and judges the part to be a silence part comprising not the voice component but only noise.例文帳に追加
音声非音声識別部106は、音声スペクトル信号とノイズベースの値の差が所定の閾値以上である場合、音声成分を含む有音部分と判定し、それ以外の場合、音声成分を含まない雑音のみの無音部分であると判定する。 - 特許庁
When a negative value is not included in the calculation result of the communication traffic estimation value and the difference thereof from the initial value vector Tin used for the calculation of the communication traffic estimation value is not larger than a predetermined threshold, a communication traffic estimation value vector Tout is output.例文帳に追加
そして、この交流トラヒック推定値の計算結果に、負の値が含まれず、かつ、この交流トラヒック推定値の計算に用いた初期値ベクトルTinとの差が所定の閾値以下であれば、この交流トラヒック推定値ベクトルToutを出力する。 - 特許庁
A control part 26 divides the whole sub-carriers into blocks constituted of continuous sub-carriers whose measured reception powers have a difference within a prescribed threshold, and determines the sub-carriers into which pilot symbols is to be inserted for each block unit, and notifies a base station 1 of the information of the sub-carriers.例文帳に追加
制御部26では、全サブキャリアを、測定した受信電力の差が所定のしきい値以内である連続するサブキャリアからなるブロックに分割し、各ブロック単位でパイロットシンボルを挿入するサブキャリアを決定し、該サブキャリアの情報を基地局1に通知する。 - 特許庁
To provide a highly reliable semiconductor device capable of preventing the occurrence of a phenomenon (hump characteristics) in which a difference is generated in sub-threshold characteristics by removing a parasitic transistor caused by shapes of a border between an STI and a element region, accompanied by micro-processing and to provide a manufacturing method thereof.例文帳に追加
微細加工に伴うSTIと素子領域の境界の形状に関る寄生トランジスタをなくし、サブスレッシホールド特性に段差ができる現象(ハンプ特性)が発生することを防止する高信頼性の半導体装置及びその製造方法を提供する。 - 特許庁
Then, a temperature propagated to a chemical inside the infusion tube is measured by temperature sensors provided on the upstream side and on the downstream side of the heater, and a difference between the temperature measured on the downstream side and the temperature measured on the upstream side and a prescribed threshold Th are compared (S5) with each other.例文帳に追加
そして、ヒータの上流側及び下流側に設けられた温度センサで、輸液チューブ内の薬液に伝播する温度を測定し、下流側で測定した温度と上流側で測定した温度との差と、所定の閾値Thとを比較する(S5)。 - 特許庁
When the number of existing persons determined by a determination unit CP2 is 0, a lighting control unit CP1 determines whether or not the difference data I_s(t) of a background image I_o obtained by a sensor S and an output image I(t) is larger than a preset threshold.例文帳に追加
点灯制御部CP1は、判定処理部CP2で判定された存在人数が0人の場合には、センサ部Sにて得られる背景画像I_oと出力画像I(t)の差分データI_s(t)が、予め設定した閾値よりも大きいか否かを判定する。 - 特許庁
The measuring display device 14 includes a calculation part 54 for secondarily differentiating the current flowing across the sensing acting electrode 48 and the sensing counter electrode 50 and a comparing decision part 56 for calculating whether the value calculated by secondary difference exceeds the threshold.例文帳に追加
計測表示器14は、検出用作用電極48と検出用対向電極50との間に流れた電流の電流値を二次差分する計算部54と、二次差分によって求められた値が閾値を超えているか否かを求める比較判定部56と、を含む。 - 特許庁
When the detection pieces 130, 140 are detected by the optical sensor 71, a determination is made on whether or not a value of elapsed time t1 being a timing difference between the detection timing of the first detection piece 130 and the detection timing of the second detection piece 140 is a first threshold value T1 or more.例文帳に追加
光学センサ71によって検出子130,140が検出されると、第1検出子130の検出タイミングと第2検出子140の検出タイミングとのタイミング差である経過時間t1の値が第1閾値T1以上であるかが判断される。 - 特許庁
| Copyright © Japan Patent office. All Rights Reserved. |
|
ログイン |
Weblio会員(無料)になると
|
|
ログイン |
Weblio会員(無料)になると
|